eBay Россия - каталог товаров аукциона eBay

Перевод

English German Russian

Все Категории

Партнеры

Загрузка...
Загрузка...
Главная

Automatic Digital Arm Blood Pressure Monitor Large BP Cuff Gauge Machine Meter

« Вернуться к результатам поиска | Размещен в категории: Health & Beauty » Health Care » Monitoring & Testing » Blood Pressure Monitoring

Номер товара: 401288893368
Продавец: hiparts (213874) 99.8% позитивных отзывов
Товар из: South San Francisco, California, US

Посмотреть товар на eBay

Состояние товара: New
Окончание аукциона: 10 д. 19 ч. 14 мин.
Купить сейчас: $6.99
Доставка в Россию: 
Товар можно заказать через компанию-посредника
Способы оплаты: 
  • PayPal
 

Краткое описание товара

Store category New Arrivals!!!Laptop KeyboardLaptop CPU FanLaptop LED/LCD/Ribbon CableLaptop LCD InverterLaptop LED/LCD HingeLaptop Floppy Drive & JackBluetoothHealth & BeautyGo Kart Minibike ClutchGoPro AccessoriesWedding Accessorieshot item 5%Car led lightSunglassesCarburetor for LawnmowersOff Road Work LightTelephone HeadsetsGenerator Voltage RegulatorOximetersautopartsScooter AccessoriesOther Sign Up Now ! You may also like FDA Auto Digital Arm Blood Pressure Monitor Large M Cuff Home BP Machine Device Product Description LotFancy FDA Portable Auto Digital Arm Blood Pressure Monitor Home Measurement BP Machine Batteries NOT included. M Cuff 8.6 to 14.2 Inches L Cuff 11.8-16.5 inches FDA approved and CE certified. Don't take chances with non-FDA approved devicesEasy to use, with automatic inflation and reading of blood pressure and heart rateEasy-to-read big 4 inch LCD display 3.31 x2.17 inchIrregular heart beat detection ,60x2 memories for 2 users ,last 3 results averageWHO blood pressure classification indicator ,low battery indicator , auto shut off function conserve your battery life1-Year Warranty: Money-back satisfaction guaranteeNote Requires 4 AA batteries (not included) or AC adaptor 6V1 A (available separately) Important Note -Be sure to order the correct size for your upper arm measurement. -Apply cuff as illustrated in the manual and tighten firmly before starting the reading. -Take blood pressure at the same time every day. In the morning shortly after getting up is best. -Avoid eating, alcohol, smoking, exercising, medications, and bathing for 30 minutes before measuring blood pressure. -Rest in a chair for 5 to 10 minutes before taking a reading. -Sit in a comfortable position and rest your arm on a table at approximately heart level for the reading. -Note that your blood pressure can vary significantly in as little as a few minutes. -For maximum accuracy you can use the option to average your last 3 readings. Feature Measurement Range Pressure: 0mmHg-300mmHg Pulse: 30-180 Beats/Minute Measurement Accuracy Pressure:±3 mmHg Pulse:±5% Pressurization Automatic Pressurization Memory 120 memories in two groups with Date and Time Unit Weight Approx. 10.72oz(Excluding Batteries) Unit Dimensions 6.54x4.49x2.83 Inches About Power Adapter UL listed, compatible with LotFancy upper arm blood pressure monitor only,NOT suitable for Omron blood pressure monitor Safe, high efficiency and reliability; automatic overload cut-off Automatic thermal cut-off; short circuit and over voltage protection,low interference & noise, Input: 100V-240V AC, output: DC 6V 1A, 5.5 x 2.1mm connector, power cord about 47 inches Connector inside positive (+) outside negative (-) 1-Year Warranty: Money-back satisfaction guarantee Compatible list: SKU and FNSKU on the package of blood pressure monitor 11A-1802-H 11A-1804-J 11C-1823-C 11C-1826-F 11C-1831-K 11C-1833-M 11C-1834-N 11C-1835-O 11C-1836-P 11C-1850-D 11C-1851-E 11C-1859-M 11C-1860-N 11C-1861-O 11C-1862-P X000N9C9SP X000N9C2NR X000TF9VDJ X000TG66S1 X000THQ0PT X000UJ9JP9 X000UIG67J X000UIJIQ5 X000UIJJ8H X000YBBAU5 X000WLAJ7R X000YBBATV X000WLI1E5 X000YXHT4J X000YXHT03 X000YXHSSB X000YXHSFT Blood pressure monitor model : BP-103H BP-1305 BP-1326 TMB-1490-C TMB-1018-A BPM61 Note: Choose the suitable cuff:too big or too small will affect the accurate reading.Cuff Application:1. Put your left arm through the cuff loop. The bottom of the cuff should be about 1 - 2 cm above your elbow(thickness of your index or middle finger). Adjust the cuff around your arm so that the tubing runs down the centre of your arm in line with your middle finger. 2. Secure the cuff around your arm using the cloth closure. Pull the cuff so that the top and bottom edges are tightened evenly around your arm. 3. Secure the cuff firmly but not too tight - just enough so that it is difficult to slide 2 fingers under the cuff. This space is imperative for an accurate reading because this digital Blood Pressure Monitors use the Oscillometric method of blood pressure measurement that detects your blood's movement through your brachial artery and converts this movement into a digital reading.Before Taking a Measurement:Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes and rest for 15 before starting the measurement. Avoid taking a measurement during stressful times. Take the measurement in a quiet place.Body Position:Sit in a chair with your feet flat on the floor. Rest your arm on a table with your palm facing upward. The cuff should be level with your heart. Do not talk or move during the measurement. For additional information please refer to the Instruction Manual for your device. Q: What is the difference between measuring blood pressure at home or at a professional healthcare clinic? A: Blood pressure readings taken at home are now seen to give a more accurate account as they better reflect your daily life. Readings can be elevated when taken in a clinical or medical environment. This is known as White Coat Hypertension and may be caused by feeling anxious or nervous. Note: Abnormal test results may be caused by: 1. Improper cuff placement Make sure cuff is snug-not too tight or too loose. Make sure bottom of the cuff is approximately 1-2cm (1/2'') above the elbow joint. 2. Improper body position Make sure to keep your body in an upright position. 3. Feeling anxious or nervous Take 2-3 deep breaths, wait a few minutes and resume testing. Q: What causes different readings? A: Blood pressure varies throughout the course of a day. Many factors including diet, stress, cuff placement, etc. may affect an individual's blood pressure. Q: Should I apply the cuff to the left or right arm? What is the difference? A: Either arm can be used when testing, however, when comparing results, the same arm should be used. Testing on your left arm may provide more accurate results as it is located closer to your heart. Q: What is the best time of day for testing? A: Morning time or any time you feel relaxed and stress free. Why do my blood pressure readings seem to vary? There are are several reasons why you may have inconsistent readings. Many factors exist that can cause a variation in blood pressure measurement values, for example, recent activities or even the time of day can alter the reading. Additionally, the user's technique is very important for reliable measurement results. Listed below are some of the common reasons you may see an inconsistent or inaccurate reading: Cuff Size It is very important to use the appropriate size cuff for your arm to obtain accurate measurement results when using your blood pressure monitor. In order to determine the appropriate cuff size, you need to measure the circumference of your arm. You should periodically measure your arm size. This is especially true if you have a borderline arm size measurement, or you may have gained or lost weight. It is important to ensure the arm cuff you are using with your monitor is the correct size for you. If the incorrect cuff is used the result may be an inaccurate reading and/or the cuff will be damaged (air bladder). To determine your arm size, use a cloth tape measure and place the tape measure midway between your elbow and your shoulder around the circumference of your upper arm. Wrap the tape measure evenly around your arm.Do not pull the tape tight. Note the precise measurement in centimetres. Cuff Application 1. Put your left arm through the cuff loop. The bottom of the cuff should be about 1 – 2 cm above your elbow (thickness of your index or middle finger). Adjust the cuff around your arm so that the tubing runs down the centre of your arm in line with your middle finger. 2. Secure the cuff around your arm using the cloth closure. Pull the cuff so that the top and bottom edges are tightened evenly around your arm. 3. Secure the cuff firmly but not too tight– just enough so that it is difficult to slide 2 fingers under the cuff. This space is imperative for an accurate reading because this digital Blood Pressure Monitors use the Oscillometric method of blood pressure measurement that detects your blood's movement through your brachial artery and converts this movement into a digital reading. Payment Delivery details Terms of sales About us Contact us Payment We accepted Paypal ONLY, All auction items must be paid in full. Shipping address must be the same as Paypal confirm address, if not, please contact and confirm with us. Delivery details All orders will be shipped within 2 business days after the payment is cleared. We use USPS First Class Service: all shipment will be with tracking number. Terms of sales We have satisfactory guarantee, if you are not satisfied with your purchase, or If by any chance you do receive a defective item please contact us and we will help to resolve your problem. Please contact us within 60 days of receipt to return it for refund or exchange. Non-defective item returns will be accepted within 14-days.There will be 15% restocking fees. Buyer is responsible for return shipping costs. About us Hiparts is a distributor of medical device , located at South San Francisco, CA 94080, Please Contact us at 9am - 5pm PST M-F for any questions if not email reply to you after 1 business day. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health: https://www.fda.gov/cdrh/devadvice/ https://www.fda.gov/cdrh/industry/support/index.html Thanks for your cooperation! "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." Contact us If you do have any questions or concerns, please feel free to contact contact via eBay's contact seller button. We will answer your email within 24 hours except Holidays, Saturday and Sunday. On Jul-10-18 at 03:07:00 PDT, seller added the following information:

Детальное описание товара

eBay
FDA Auto Digital Arm Blood Pressure Monitor Large M Cuff Home BP Machine Device

Product Description

LotFancy FDA Portable Auto Digital Arm Blood Pressure Monitor Home Measurement BP Machine

                             
                 Batteries NOT included.
                        

M Cuff 8.6 to 14.2 Inches

L Cuff 11.8-16.5 inches

  • FDA approved and CE certified. Don't take chances with non-FDA approved devices
  • Easy to use, with automatic inflation and reading of blood pressure and heart rate
  • Easy-to-read big 4 inch LCD display 3.31 x2.17 inch
  • Irregular heart beat detection ,60x2 memories for 2 users ,last 3 results average
  • WHO blood pressure classification indicator ,low battery indicator , auto shut off function conserve your battery life
  • 1-Year Warranty: Money-back satisfaction guarantee
Note Requires 4 AA batteries (not included) or AC adaptor 6V1 A (available separately)

Important Note
-Be sure to order the correct size for your upper arm measurement.
-Apply cuff as illustrated in the manual and tighten firmly before starting the reading.
-Take blood pressure at the same time every day. In the morning shortly after getting up is best.
-Avoid eating, alcohol, smoking, exercising, medications, and bathing for 30 minutes before measuring blood pressure.
-Rest in a chair for 5 to 10 minutes before taking a reading.
-Sit in a comfortable position and rest your arm on a table at approximately heart level for the reading.
-Note that your blood pressure can vary significantly in as little as a few minutes.
-For maximum accuracy you can use the option to average your last 3 readings.

Feature

Measurement Range
Pressure: 0mmHg-300mmHg
Pulse: 30-180 Beats/Minute

Measurement Accuracy
Pressure:±3 mmHg
Pulse:±5%

Pressurization
Automatic Pressurization

Memory
120 memories in two groups
with Date and Time

Unit Weight
Approx. 10.72oz(Excluding Batteries)

Unit Dimensions
6.54x4.49x2.83 Inches

About Power Adapter

 UL listed, compatible with LotFancy upper arm blood pressure monitor only,NOT suitable for  Omron blood pressure monitor
Safe, high efficiency and reliability; automatic overload cut-off
Automatic thermal cut-off; short circuit and over voltage protection,low interference & noise,
Input: 100V-240V AC, output: DC 6V 1A, 5.5 x 2.1mm connector, power cord about 47 inches
Connector inside positive (+) outside negative (-)
1-Year Warranty: Money-back satisfaction guarantee

Compatible list:

SKU and FNSKU  on the package of blood pressure monitor
11A-1802-H 11A-1804-J 11C-1823-C 11C-1826-F  11C-1831-K 11C-1833-M 11C-1834-N 11C-1835-O
11C-1836-P 11C-1850-D 11C-1851-E 11C-1859-M 11C-1860-N 11C-1861-O 11C-1862-P X000N9C9SP
X000N9C2NR X000TF9VDJ X000TG66S1 X000THQ0PT X000UJ9JP9 X000UIG67J X000UIJIQ5 X000UIJJ8H
X000YBBAU5 X000WLAJ7R X000YBBATV X000WLI1E5 X000YXHT4J X000YXHT03 X000YXHSSB X000YXHSFT
Blood pressure monitor model :
BP-103H  BP-1305  BP-1326  TMB-1490-C  TMB-1018-A  BPM61





Note:

Choose the suitable cuff:too big or too small will affect the accurate reading.
Cuff Application:1. Put your left arm through the cuff loop. The bottom of the cuff should be about 1 - 2 cm above
 your elbow(thickness of your index or middle finger). Adjust the cuff around your arm so that the tubing runs down
 the centre of your arm in line with your middle finger.
2. Secure the cuff around your arm using the cloth closure. Pull the cuff so that the top and bottom edges are 
tightened evenly around your arm.
3. Secure the cuff firmly but not too tight - just enough so that it is difficult to slide 2 fingers under the cuff. This space is
 imperative for an accurate reading because this digital Blood Pressure Monitors use the Oscillometric method of blood
 pressure measurement that detects your blood's movement through your brachial artery and converts this movement 
into a digital reading.Before Taking a Measurement:Avoid eating, drinking alcohol, smoking, exercising, and bathing for
 30 minutes and rest for 15 before starting the measurement. Avoid taking a measurement during stressful times. 
Take the measurement in a quiet place.Body Position:Sit in a chair with your feet flat on the floor. Rest your arm on 
a table with your palm facing upward. The cuff should be level with your heart. Do not talk or move during the 
measurement.
For additional information please refer to the Instruction Manual for your device.
Q: What is the difference between measuring blood pressure at home or at a professional
healthcare clinic?
A: Blood pressure readings taken at home are now seen to give a more accurate account as
they better reflect your daily life. Readings can be elevated when taken in a clinical or
medical environment. This is known as White Coat Hypertension and may be caused by
feeling anxious or nervous.
Note: Abnormal test results may be caused by:
1. Improper cuff placement
Make sure cuff is snug-not too tight or too loose.
Make sure bottom of the cuff is approximately 1-2cm (1/2'') above the elbow
joint.
2. Improper body position
Make sure to keep your body in an upright position.
3. Feeling anxious or nervous
Take 2-3 deep breaths, wait a few minutes and resume testing.
Q: What causes different readings?
A: Blood pressure varies throughout the course of a day. Many factors including diet,
stress, cuff placement, etc. may affect an individual's blood pressure.
Q: Should I apply the cuff to the left or right arm? What is the difference?
A: Either arm can be used when testing, however, when comparing results, the same arm
should be used. Testing on your left arm may provide more accurate results as it is
located closer to your heart.
Q: What is the best time of day for testing?
A: Morning time or any time you feel relaxed and stress free.

 Why do my blood pressure readings seem to vary?

There are are several reasons why you may have inconsistent readings. Many factors exist that can
cause a variation in blood pressure measurement values, for example, recent activities or even the time
of day can alter the reading. Additionally, the user's technique is very important for reliable measurement
results. Listed below are some of the common reasons you may see an inconsistent or inaccurate reading:

Cuff Size It is very important to use the appropriate size cuff for your arm to obtain accurate measurement 
results when using your blood pressure monitor. In order to determine the appropriate cuff size, you need to 
measure the circumference of your arm. You should periodically measure your arm size. This is especially 
true if you have a borderline arm size measurement, or you may have gained or lost weight. It is important to
 ensure the arm cuff you are using with your monitor is the correct size for you. If the incorrect cuff is used 
the result may be an inaccurate reading and/or the cuff will be damaged (air bladder). To determine your arm 
size, use a cloth tape measure and place the tape measure midway between your elbow and your shoulder 
around the circumference of your upper arm. Wrap the tape measure evenly around your arm.
Do not pull the tape tight. Note the precise measurement in centimetres.

Cuff Application 
1. Put your left arm through the cuff loop. The bottom of the cuff should be about 1 – 2 cm above your elbow
(thickness of your index or middle finger). Adjust the cuff around your arm so that the tubing runs down the centre
of your arm in line with your middle finger. 2. Secure the cuff around your arm using the cloth closure. 
Pull the cuff so that the top and bottom edges are tightened evenly around your arm.  3. Secure the cuff firmly 
but not too tight– just enough so that it is difficult to slide 2 fingers under the cuff.
This space is imperative for an accurate reading because this digital Blood Pressure Monitors use the
Oscillometric method of blood pressure measurement that detects your blood's movement through your
brachial artery and converts this movement into a digital reading.

We accepted Paypal ONLY,

All auction items must be paid in full.

Shipping address must be the same as Paypal confirm address, if not, please contact and confirm with us.
All orders will be shipped within 2 business days after the payment is cleared.

We use USPS First Class Service: all shipment will be with tracking number.
We have satisfactory guarantee, if you are not satisfied with your purchase, or If by any chance you do receive a defective

item please contact us and we will help to resolve your problem.

Please contact us within 60 days of receipt to return it for refund or exchange.

Non-defective item returns will be accepted within 14-days.There will be 15% restocking fees.

Buyer is responsible for return shipping costs.
Hiparts is a distributor of medical device , located at South San Francisco, CA 94080, Please Contact us at 9am - 5pm

PST M-F for any questions if not email reply to you after 1 business day.

If you have questions about legal obligations regarding sales of medical devices, you should consult with the

FDA's Center for Devices and Radiological Health:

https://www.fda.gov/cdrh/devadvice/

https://www.fda.gov/cdrh/industry/support/index.html

Thanks for your cooperation!


"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory

agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation,

I will verify your status as an authorized purchaser of this item before shipping of the item."
If you do have any questions or concerns, please feel free to contact contact via eBay's contact seller button.

We will answer your email within 24 hours except Holidays, Saturday and Sunday.
PushAuction


On Jul-10-18 at 03:07:00 PDT, seller added the following information:

DataCaciques

« Вернуться к результатам поиска

Загрузка...